LOYOLA COLLEGE (AUTONOMOUS), CHENNAI – 600 034
M.Sc. DEGREE EXAMINATION – MEDICAL LAB TECHNOLOGY
|
FOURTH SEMESTER – APRIL 2006
ML 4805 – NON INVASIVE TECHNIQUES
(Also equivalent to ML 4801)
Date & Time : 20-04-2006/FORENOON Dept. No. Max. : 100 Marks
Part A (Answer All) 10 ´ 2 = 20
- Name the four types of electrode system.
- What is heart block? Mention its types.
- Define montage electrode selector.
- Name the two types of computed tomography.
- What are the four basic densities on an X ray and mention the colour which appears on the X ray film.
- Mention the interfering factors that occur while performing electroencephalography.
- What are the causes for hyperfluorescence and hypofluorescence.
- List the four MRI methods that are available for examination.
- Name the three tests that are performed in evoked potential studies.
- What are invasive and non-invasive techniques.
Part B (Answer any four) 4 ´ 10 = 40
- Write the principle and working mechanism of electroencephalography.
- Describe visual acuity in detail.
- Describe the principle of X ray. Mention its types and uses.
- Explain the principle of Doppler ultrasonography.
- Explain principle, procedure and limitations of MRI.
- Explain the principle and recording set up of electromyography.
Part C (Answer any two) 2 ´ 20 = 40
- Explain in detail the principle, procedure and recordings of ECG.
- Describe in detail the Transcranial Doppler studies.
- Explain positron emission tomography in detail.
- Explain the principle, procedure and working mechanism of computed tomography.